Description

The PLM 12K44 Combines a 4-in, 4-out Configuration with Industry-standard Dante Networking, Setting the Benchmark for Powered Loudspeaker Management Systems.

The PLM 12K44 is the natural successor of the proven, road tested, and trusted Lab Gruppen touring foundation exemplified by the iconic PLM series, but with an additional new powerful feature set: the ability to rationalize power allocation between channels to optimize performance. Now packaged in an extended 4-in, 4-out configuration together with twice the processing power via the latest version 6.3 Lake Controller release, plus industry-standard Dante® networking, the PLM 12K44 sets the benchmark for Powered Loudspeaker Management Systems.

 

Features

  • 12,000 Watt amplifier with 4 flexible output channels and up to 5,900 Watts channel output for touring applications
  • Lake digital signal processing for unparalleled loudspeaker management and system control
  • Integrated 8×8 channels of dual redundant Dante* digital audio networking with AES67 support
  • 4 x 3,000 Watts into 2 Ohms, 4 x 3,000 Watts into 2.67 Ohms, 4 x 3,000 Watts into 4 Ohms, 4 x 1,900 Watts into 8 Ohms, 4 x 950 Watts into 16 Ohms, 4 x 3,000 Watts into Hi-Z 70 V, 4 x 3,000 Watts into Hi-Z 100 V
  • Proven and reliable Class-TD output stage with proprietary Intercooler high-efficiency cooling system
  • Rational Power Management (RPM) provides total flexibility to allocate available power across all 4 output channels
  • Best-in-class Power Factor Correction (PFC) with Current Draw Modelling reduces running costs and minimizes environmental impact
  • Under-Voltage Limiting (UVL) for continued operation during severe mains supply voltage drops
  • Dedicated on-board surveillance and load monitoring for complete peace of mind
  • Redundant audio inputs and on-board system surveillance for full system security
  • Backlit, white-on-black front panel display and menu navigation buttons
  • 100 user presets for simple and efficient system configuration and set-up
  • 3 front-to-rear airflow fans with temperature control for optimal speed and reduced noise
  • 4 “Lake Class” analog input channels with Iso-Float ground isolation
  • 4 input channels of AES/EBU (AES3) digital audio supporting all standard sample rates up to 192 kHz with 24-bit resolution
  • 2 Neutrik etherCON* RJ-45 ports provide dual redundant Dante interfaces and remote configuration via Lake Controller and Dante Controller software
  • Balanced analog and AES/EBU audio inputs on Neutrik* XLR connectors
  • Rugged binding post output connectors
  • Detachable Neutrik powerCON* cable rated at 250 V / 32 A
  • Removable dust filter grilles for increased air circulation
  • Rugged 2U rackmount chassis for durability in touring applications

 

Specifications

General
Processing / Network

Lake / Dante

Number of amplifier channels

4

Total burst power all channels (share among channels with RPM)

12000 W

Max output power (all channels driven)1
2 ohms

3000 W

2.67 ohms

3000 W

4 ohms

3000 W

8 ohms

1900 W

16 ohms

950 W

Hi-Z 70 V

3000 W

Hi-Z 100 V

3000 W

Max output power single channel1
2 ohms

4400 W

2.67 ohms

5900 W

4 ohms

4600 W

8 ohms

2300 W

16 ohms

1150 W

Hi-Z 70 V

3300 W

Hi-Z 100 V

4700 W

Amplifier output modules (all models, all channels)
Peak output voltage

194 V

Max. output current

67 A

Rational Power Management (RPM)

Regardless of model, any channel has potential to deliver the max single channel output power

Default voltage limitation (can be lifted with RPM configuration)

175 V

Protection features

Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection

Audio Performance (Amplifier platform with digital input)
THD + N 20 Hz – 20 kHz for 1 W

< 0.05 %

THD + N at 1 kHz and 1 dB below clipping

< 0.04 %

Dynamic range

> 114 dB

Channel separation (Crosstalk) at 1 kHz

> 70 dB

Frequency response (1 W into 8 Ohm, 20 Hz – 20 kHz)

+/- 0.05 dB

Internal Sample Rate / Data path

48 / 96 kHz / 32 bit floating point

Product propagation delay AES 96 kHz / analog input

1.61 / 1.68 ms

Lake processing
Loudspeaker processing

Up to 4 modules of Classic/linear-phase/FIR crossover, EQ, delay, LimiterMax™ – peak and RMS limiters

System tuning

Group control with Raised Cosine™ MESA EG™ asymmetric filters

Input redundancy / Matrix

Automatic 4 level input redundancy / 4 input mixers

System integration

Comprehensive 3rd party protocol over UDP Ethernet

Measurement & Analysis
Pilot tone generation and analysis

Yes

Load impedance analysis

Yes

Real Time Analyzer (RTA), 3rd party integration

Yes

Dante Audio Network
Dante I/O

8 x 8

Network topology / redundancy

Flexible topology / Supports daisy-chained and Dual redundant networks

Sample Rates / Transport

48, 96 kHz / Uni + Multicast

Network latency

0.25, 0.5, 1.0, 2.0, 5.0 ms

Device presets
Local memory locations for the settings of the product

100

AES Inputs
Inputs

4 AES inputs

Supported sample rates / resolution

44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits

Sample rate conversion THD+N 20 Hz – 20 kHz unweighted

0.0000003

Analog Inputs
Inputs

4 high quality inputs with Iso-Float ground isolation

Maximum input / digital reference

+26 dBu / +21 dBu

Sampling rate / Resolution

96 kHz / 24 bit

Input impedance balanced / unbalanced

20 / 10 kOhm

THD+N (typical at 1 kHz unweighted)

0.0000022

THD+N (typical at 20 Hz and 20 kHz unweighted)

0.0000033

Limiters
Adjustable Inter-Sample Voltage Peak Limiter (ISVPL)

17.8 – 194 V, step size 0.1 V

Current Peak Limiter < 300 ms

67 A peak

Current Average Limiter (CAL) > 300 ms

33 Arms

MaxRMS (rms voltage limiter)

Yes

MaxPeak (peak voltage limiter)

Yes

Gain
Amplifier gain

22 – 44 dB, step size 0.1 dB

Output attenuator

-Inf to 0 dB, step size 0.25 dB

Back panel Interface
Analog, 2-channel I/O (input + link)

4 x 3-pin XLR, electronically balanced

AES / EBU / I/O (input + link)

2 x 3-pin XLR

Output connectors

Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs)

Auto 10/100, Auto Uplink

2 x RJ45 etherCON

Control and monitoring interface

Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol)

Detachable mains cord

Neutrik PowerCon rated at 250V/32A

Cooling

Three fans, front-rear airflow, temperature controlled speed

Front-panel user interface
Display

2.5 inch, black / white, daylight readable LCD

Fault/Warning/Limit/Clip indicators

RGB LEDs and detailed fault description on display

Mute and soft function buttons

8 provided

Standby Power button

On/Standby

Mute Enable button

Enables muting of outputs and inputs via soft-button keypad

Meter button

Toggles through meter views

Menu button

Provides a menu driven interface for full function front panel control

Rotary Encoder

Yes

Exit Button

Provides a “back” function

Mains Power
Nominal voltage

100 – 240 Volt AC 45 – 66 Hz

Operating voltage

70-265 V AC

Mains wall plug

NEMA L5-30 “Twist lock” 125 V / 30 A, and CEE 7/7 “Schuko” 230 V / 16 A

Power supply features
Soft start / Inrush power

Yes/ Max 8 Ampere

Power Factor Correction (PFC)

0.98

Regulated switch mode power supply (R.SMPS)

Yes

Breaker Emulation Limiter (BEL)

Configurable current threshold and breaker profile

BEL max current threshold

25 A

Power Average Limiter (PAL)

Yes

Under Voltage Limiter (UVL)

Yes

Mains undervoltage and overvoltage protection and mains glitch tolerance

Yes

Dimensions
Rack rail to rear panel

W: 483 mm (19″), H: 88 mm (2 U), D: 424 mm (16″)

Overall depth front-rear support

D: 498 mm (19.6″)

Weight
Weight

16.5 kg (36 lbs)

Finish
Finish

Black painted steel chassis with black painted steel / aluminum front

Approvals
Approvals

CE, ANSI / UL 60065 (ETL), CSA C22.2 NO. 60065, FCC, PSE, RCM, BIS India

 

 

Additional information
Brand

Lab Gruppen

Reviews (0)
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews